Zheng D. O'Neill
Título
Citado por
Citado por
Ano
A methodology for meta-model based optimization in building energy models
B Eisenhower, Z O’Neill, S Narayanan, VA Fonoberov, I Mezić
Energy and Buildings 47, 292-301, 2012
2482012
Uncertainty and sensitivity decomposition of building energy models
B Eisenhower, Z O'Neill, VA Fonoberov, I Mezić
Journal of Building Performance Simulation 5 (3), 171-184, 2012
1902012
An optimal and learning-based demand response and home energy management system
D Zhang, S Li, M Sun, Z O’Neill
IEEE Transactions on Smart Grid 7 (4), 1790-1801, 2016
1592016
A BIM-enabled information infrastructure for building energy Fault Detection and Diagnostics
B Dong, Z O'Neill, Z Li
Automation in Construction 44, 197-211, 2014
1272014
Integrating home energy simulation and dynamic electricity price for demand response study
S Li, D Zhang, AB Roget, Z O'Neill
IEEE Transactions on Smart Grid 5 (2), 779-788, 2013
1222013
Comparisons of inverse modeling approaches for predicting building energy performance
Y Zhang, Z O'Neill, B Dong, G Augenbroe
Building and Environment 86, 177-190, 2015
1212015
A study of geothermal heat pump and standing column well performance
SJ Rees, JD Spitler, Z Deng, CD Orio, CN Johnson
ASHRAE Transactions 110 (1), 3-13, 2004
1012004
Modeling of Standing Column Wells in Ground Source Heat Pump Systems.
ZDJDS O’Neill
The 10 th International Conference on Thermal Energy Storage. Richard …, 2006
98*2006
Model-based thermal load estimation in buildings
Z O'Neill, S Narayanan, R Brahme
Proceedings of simbuild 4 (1), 474-481, 2010
822010
Building energy doctors: An SPC and Kalman filter-based method for system-level fault detection in HVAC systems
B Sun, PB Luh, QS Jia, Z O'Neill, F Song
IEEE Transactions on Automation Science and Engineering 11 (1), 215-229, 2013
752013
Leveraging the analysis of parametric uncertainty for building energy model calibration
Z O’Neill, B Eisenhower
Building simulation 6 (4), 365-377, 2013
692013
A model for annual simulation of standing column well ground heat exchangers
Z Deng, SJ Rees, JD Spitler
Hvac&R Research 11 (4), 637-655, 2005
652005
Model-based real-time whole building energy performance monitoring and diagnostics
Z O'Neill, X Pang, M Shashanka, P Haves, T Bailey
Journal of Building Performance Simulation 7 (2), 83-99, 2014
632014
A Survey of Standing Column Well Installations in North America.
CD Orio, A Chiasson, CN Johnson, Z Deng, SJ Rees, JD Spitler
ASHRAE transactions 111 (2), 2005
572005
Evaluation of “Autotune” calibration against manual calibration of building energy models
G Chaudhary, J New, J Sanyal, P Im, Z O’Neill, V Garg
Applied energy 182, 115-134, 2016
552016
Uncertainty and sensitivity analysis of spatio-temporal occupant behaviors on residential building energy usage utilizing Karhunen-Loève expansion
Z O'Neill, F Niu
Building and Environment 115, 157-172, 2017
432017
Development of a probabilistic graphical model for predicting building energy performance
Z O’Neill, C O’Neill
Applied energy 164, 650-658, 2016
422016
Performance analysis of standing column well ground heat exchanger systems
ZD O'Neill, JD Spitler, S Rees
ASHRAE transactions 112 (2), 633-644, 2006
422006
Real-time building energy simulation using EnergyPlus and the Building Controls Virtual Test Bed
X Pang, P Bhattacharya, Z O’Neill, P Haves, M Wetter, T Bailey
Proceeding of the 12th IBPSA Conference, 2890-2896, 2011
372011
Uncertainty quantification and sensitivity analysis of the domestic hot water usage in hotels
Z Pang, Z O'Neill
Applied energy 232, 424-442, 2018
362018
O sistema não pode efectuar a operação agora. Tente novamente mais tarde.
Artigos 1–20