Follow
R. Scott Hinks
R. Scott Hinks
GE Healthcare
Verified email at med.ge.com
Title
Cited by
Cited by
Year
Time course EPI of human brain function during task activation
PA Bandettini, EC Wong, RS Hinks, RS Tikofsky, JS Hyde
Magnetic resonance in medicine 25 (2), 390-397, 1992
25831992
Spin‐echo and gradient‐echo EPI of human brain activation using BOLD contrast: a comparative study at 1.5 T
PA Bandettini, EC Wong, A Jesmanowicz, RS Hinks, JS Hyde
NMR in Biomedicine 7 (1‐2), 12-20, 1994
4161994
Ex vivo tissue‐type independence in proton‐resonance frequency shift MR thermometry
RTD Peters, RS Hinks, RM Henkelman
Magnetic resonance in medicine 40 (3), 454-459, 1998
3921998
A multispectral three‐dimensional acquisition technique for imaging near metal implants
KM Koch, JE Lorbiecki, RS Hinks, KF King
Magnetic Resonance in Medicine: An Official Journal of the International …, 2009
3252009
Cine MR in the evaluation of normal and abnormal CSF flow: intracranial and intraspinal studies
RM Quencer, MJ Donovan Post, RS Hinks
Neuroradiology 32, 371-391, 1990
2841990
Real‐time shimming to compensate for respiration‐induced B0 fluctuations
P van Gelderen, JA De Zwart, P Starewicz, RS Hinks, JH Duyn
Magnetic Resonance in Medicine: An Official Journal of the International …, 2007
2282007
Prostate cancer: MR imaging and thermometry during microwave thermal ablation-initial experience
JC Chen, JA Moriarty, JA Derbyshire, RD Peters, J Trachtenberg, SD Bell, ...
Radiology 214 (1), 290-297, 2000
1702000
Heat‐source orientation and geometry dependence in proton‐resonance frequency shift magnetic resonance thermometry
RD Peters, RS Hinks, RM Henkelman
Magnetic Resonance in Medicine: An Official Journal of the International …, 1999
1281999
Dynamic scan‐plane tracking using MR position monitoring
JA Derbyshire, GA Wright, RM Henkelman, RS Hinks
Journal of magnetic resonance imaging 8 (4), 924-932, 1998
1251998
Separation of fat and water in fast spin‐echo MR imaging with the three‐point Dixon technique
PA Hardy, RS Hinks, JA Tkach
Journal of Magnetic Resonance Imaging 5 (2), 181-185, 1995
1151995
Stabilization of echo amplitudes in FSE sequences
PL Roux, RS Hinks
Magnetic resonance in medicine 30 (2), 183-190, 1993
1081993
MR evaluation of vertebral metastases: T1-weighted, short-inversion-time inversion recovery, fast spin-echo, and inversion-recovery fast spin-echo sequences.
RC Mehta, MP Marks, RS Hinks, GH Glover, DR Enzmann
American journal of neuroradiology 16 (2), 281-288, 1995
1001995
MR systems for image‐guided therapy
RS Hinks, MJ Bronskill, W Kucharczyk, M Bernstein, BD Collick, ...
Journal of magnetic resonance imaging 8 (1), 19-25, 1998
981998
Comparison of thermal damage calculated using magnetic resonance thermometry, with magnetic resonance imaging post-treatment and histology, after interstitial microwave thermal …
MD Sherar, JA Moriarty, MC Kolios, JC Chen, RD Peters, LC Ang, ...
Physics in Medicine & Biology 45 (12), 3563, 2000
972000
Phase and amplitude correction for multi‐echo water–fat separation with bipolar acquisitions
H Yu, A Shimakawa, CA McKenzie, W Lu, SB Reeder, RS Hinks, ...
Journal of Magnetic Resonance Imaging: An Official Journal of the …, 2010
912010
Gradient moment nulling in fast spin echo
RS Hinks, RT Constable
Magnetic resonance in medicine 32 (6), 698-706, 1994
901994
Magnetic resonance imaging of temperature changes during interstitial microwave heating: a phantom study
IA Vitkin, JA Moriarty, RD Peters, MC Kolios, AS Gladman, JC Chen, ...
Medical Physics 24 (2), 269-277, 1997
841997
Recommendations towards standards for quantitative MRI (qMRI) and outstanding needs
KE Keenan, JR Biller, JG Delfino, MA Boss, MD Does, JL Evelhoch, ...
Journal of magnetic resonance imaging: JMRI 49 (7), e26, 2019
822019
Dynamic scan plane tracking using MR position monitoring
JA Derbyshire, RS Hinks, GA Wright, RM Henkelman
US Patent 5,947,900, 1999
731999
MRI monitoring of interstitial microwave‐induced heating and thermal lesions in rabbit brain in vivo
JA Moriarty, JC Chen, CM Purcell, LC Ang, RS Hinks, RD Peters, ...
Journal of Magnetic Resonance Imaging 8 (1), 128-135, 1998
601998
The system can't perform the operation now. Try again later.
Articles 1–20