The influence of finishing milling strategies on texture, roughness and dimensional deviations on the machining of complex surfaces AM Ramos, C Relvas, JA Simoes Journal of Materials Processing Technology 136 (1-3), 209-216, 2003 | 119 | 2003 |
Straight, semi-anatomic and anatomic TMJ implants: the influence of condylar geometry and bone fixation screws A Ramos, A Completo, C Relvas, M Mesnard, JA Simões Journal of Cranio-Maxillofacial Surgery 39 (5), 343-350, 2011 | 84 | 2011 |
The sheep as an animal model in orthopaedic research JC Potes, J Reis, F Capela e Silva, C Relvas, AS Cabrita, JA Simões | 53 | 2008 |
Biomechanical evaluation of proximal tibia behaviour with the use of femoral stems in revision TKA: an in vitro and finite element analysis A Completo, A Rego, F Fonseca, A Ramos, C Relvas, JA Simões Clinical biomechanics 25 (2), 159-165, 2010 | 51 | 2010 |
Design process of a novel cemented hip femoral stem concept A Ramos, A Completo, C Relvas, JA Simoes Materials & Design 33, 313-321, 2012 | 42 | 2012 |
Biomechanical evaluation of different reconstructive techniques of proximal tibia in revision total knee arthroplasty: An in-vitro and finite element analysis A Completo, R Duarte, F Fonseca, JA Simões, A Ramos, C Relvas Clinical Biomechanics 28 (3), 291-298, 2013 | 34 | 2013 |
Biomechanical analysis of total elbow replacement with unlinked iBP prosthesis: an in vitro and finite element analysis A Completo, J Pereira, F Fonseca, A Ramos, C Relvas, J Simões Clinical Biomechanics 26 (10), 990-997, 2011 | 31 | 2011 |
Vacuum casting with room temperature vulcanising rubber and aluminium moulds for rapid manufacturing of quality parts: a comparative study AM Ramos, C Relvas, JA Simo˜ es Rapid Prototyping Journal 9 (2), 111-115, 2003 | 31 | 2003 |
A new press-fit stem concept to reduce the risk of end-of-stem pain at revision TKA: a pre-clinical study A Completo, F Fonseca, JA Simões, A Ramos, C Relvas The Knee 19 (5), 537-542, 2012 | 29 | 2012 |
Accuracy control of complex surfaces in reverse engineering C Relvas, A Ramos, A Completo, JA Simões International Journal of Precision Engineering and Manufacturing 12, 1035-1042, 2011 | 28 | 2011 |
A systematic approach for an accuracy level using rapid prototyping technologies C Relvas, A Ramos, A Completo, JA Simões Proceedings of the Institution of Mechanical Engineers, Part B: Journal of …, 2012 | 26 | 2012 |
The design of a washing machine prototype A Sérgio, J Duarte, C Relvas, R Moreira, R Freire, JL Ferreira, JA Simões Materials & design 24 (5), 331-338, 2003 | 25 | 2003 |
O Mundo da Impressão 3D e o Fabrico Digital C Relvas Quântica Editora–Conteúdos Especializados, Lda, 2018 | 23 | 2018 |
Improved stability with intramedullary stem after anterior femoral notching in total knee arthroplasty A Completo, F Fonseca, C Relvas, A Ramos, JA Simões Knee Surgery, Sports Traumatology, Arthroscopy 20, 487-494, 2012 | 23 | 2012 |
Controlo numérico computorizado: conceitos fundamentais C Relvas | 21 | 2002 |
Theoretical assessment of an intramedullary condylar component versus screw fixation for the condylar component of a hemiarthroplasty alloplastic TMJ replacement system A Ramos, M Mesnard, C Relvas, A Completo, JA Simões Journal of Cranio-Maxillofacial Surgery 42 (2), 169-174, 2014 | 19 | 2014 |
The influence of acetabular bone cracks in the press-fit hip replacement: Numerical and experimental analysis A Ramos, RJ Duarte, C Relvas, A Completo, JA Simões Clinical biomechanics 28 (6), 635-641, 2013 | 17 | 2013 |
Concepção e Estudo De prótese Da Anca Anatomicamente Adaptados Por obtenção in Situ Da Geometria Do Canal Femoral CAM Relvas PQDT-Global, 2007 | 17 | 2007 |
New methodology for product development process using structured tools C Relvas, A Ramos Proceedings of the Institution of Mechanical Engineers, Part B: Journal of …, 2021 | 12 | 2021 |
Project-based teaching–learning computer-aided engineering tools JA Simões, C Relvas, R Moreira European journal of engineering education 29 (1), 147-161, 2004 | 11 | 2004 |