Follow
Elsa Batista
Elsa Batista
Responsável de laboratório de volume, IPQ
Verified email at ipq.pt
Title
Cited by
Cited by
Year
Primary standards for measuring flow rates from 100 nl/min to 1 ml/min–gravimetric principle
H Bissig, HT Petter, P Lucas, E Batista, E Filipe, N Almeida, LF Ribeiro, ...
Biomedical Engineering/Biomedizinische Technik 60 (4), 301-316, 2015
632015
Calibration of micropipettes: Test methods and uncertainty analysis
E Batista, L Pinto, E Filipe, AMH Van der Veen
Measurement 40 (3), 338-342, 2007
462007
Assessment of drug delivery devices
E Batista, N Almeida, A Furtado, E Filipe, L Sousa, R Martins, P Lucas, ...
Biomedical Engineering/Biomedizinische Technik 60 (4), 347-357, 2015
372015
The selection of water property formulae for volume and flow calibration
E Batista, R Paton
Metrologia 44 (6), 453, 2007
352007
Measurement of density using oscillation-type density meters calibration, traceability and uncertainties
A Furtado, E Batista, I Spohr, E Filipe
Proceedings of the 14ème Congrès International de Métrologie, 2009
282009
New EMPIR project–Metrology for drug delivery
E Batista, A Furtado, J Pereira, M Ferreira, H Bissig, E Graham, ...
Flow Measurement and Instrumentation 72, 101716, 2020
262020
Experimental testing for metrological traceability and accuracy of liquid microflows and microfluidics
E Batista, JA Sousa, S Cardoso, V Silverio
Flow Measurement and Instrumentation 71, 101691, 2020
212020
Development of an experimental setup for microflow measurement using interferometry
E Batista, I Godinho, RF Martins, R Mendes, J Robarts
Flow Measurement and Instrumentation 75, 101789, 2020
182020
Comparison of infusion pumps calibration methods
E Batista, I Godinho, M do Céu Ferreira, A Furtado, P Lucas, C Silva
Measurement science and technology 28 (12), 124003, 2017
152017
Volume calibration of 1000 μl micropipettes. Inter-laboratory comparison
E Batista, E Filipe, B Mickan
Accreditation and Quality Assurance 13, 261-266, 2008
132008
Uncertainty calculation in gravimetric microflow measurements
E Batista, N Almeida, I Godinho, E Filipe
Advanced Mathematical and Computational Tools in Metrology and Testing X, 98-104, 2015
112015
Final report on BIPM/CIPM key comparison CCM. FF-K4. 2.2011: Volume comparison at 100 µL—Calibration of micropipettes (piston pipettes)
E Batista, R Arias, W Jintao
Metrologia 50 (1A), 07003-07003, 2013
112013
Ultra-low flow rate measurement techniques
E Graham, K Thiemann, S Kartmann, E Batista, H Bissig, A Niemann, ...
Measurement: Sensors 18, 100279, 2021
92021
Quality assurance of volumetric glassware for the determination of vitamins in food
I Castanheira, E Batista, A Valente, G Dias, M Mora, L Pinto, HS Costa
Food control 17 (9), 719-726, 2006
92006
The selection of water property formulae for volume and flow calibration and measurement
E Batista, R Paton
Metrologia 55 (5), 731, 2018
82018
Method selection to evaluate measurement uncertainty in microflow applications
JA Sousa, E Batista, O Pellegrino, AS Ribeiro, LL Martins
Journal of Physics: Conference Series 1379 (1), 012033, 2019
72019
A study of factors that influence micropipette calibrations
E Batista, N Almeida, E Filipe
NCSLI Measure 10 (1), 60-66, 2015
72015
Calibration of infusion pumps using liquids whose physical properties differ from those of water
E Batista, A Furtado, N Almeida, S Moura, R Martins, L Sousa, E Filipe
Journal of Physics: Conference Series 588 (1), 012053, 2015
72015
Calibration and use of syringe pumps
E Batista, N Almeida, E Filipe, A Costa
16th International Congress of Metrology, 02007, 2013
72013
Measurement of internal diameters of capillaries and glass syringes using gravimetric and optical methods for microflow applications
E Batista, M Álvares, RF Martins, F Ogheard, J Geršl, I Godinho
Biomedical Engineering/Biomedizinische Technik 68 (1), 29-38, 2023
62023
The system can't perform the operation now. Try again later.
Articles 1–20