Vítor Leal
Vítor Leal
Department of Mechanical Engineering, University of Porto
Email confirmado em fe.up.pt
Título
Citado por
Citado por
Ano
A methodology for economic efficient design of Net Zero Energy Buildings
M Kapsalaki, V Leal, M Santamouris
Energy and Buildings 55, 765-778, 2012
1842012
Energy sustainability indicators for local energy planning: Review of current practices and derivation of a new framework
AR Neves, V Leal
Renewable and Sustainable Energy Reviews 14 (9), 2723-2735, 2010
1602010
Building envelope shape design in early stages of the design process: Integrating architectural design systems and energy simulation
V Granadeiro, JP Duarte, JR Correia, VMS Leal
Automation in Construction 32, 196-209, 2013
1562013
Occupants interaction with electric lighting and shading systems in real single-occupied offices: Results from a monitoring campaign
PC da Silva, V Leal, M Andersen
Building and Environment 64, 152-168, 2013
1152013
Influence of shading control patterns on the energy assessment of office spaces
PC da Silva, V Leal, M Andersen
Energy and Buildings 50, 35-48, 2012
1112012
The relevance of the energy resource dynamics in the mid/long-term energy planning models
G Haydt, V Leal, A Pina, CA Silva
Renewable energy 36 (11), 3068-3074, 2011
1052011
Envelope-related energy demand: A design indicator of energy performance for residential buildings in early design stages
V Granadeiro, JR Correia, VMS Leal, JP Duarte
Energy and Buildings 61, 215-223, 2013
852013
Recent progress on net zero energy buildings
M Kapsalaki, V Leal
Advances in Building Energy Research 5 (1), 129-162, 2011
812011
Measurement of air temperature in the presence of a large radiant flux: an assessment of passively ventilated thermometer screens
E Erell, V Leal, E Maldonado
Boundary-layer meteorology 114 (1), 205-231, 2005
712005
Characterization of thermal performance and nominal heating gap of the residential building stock using the EPBD-derived databases: The case of Portugal mainland
SMC Magalhães, VMS Leal
Energy and Buildings 70, 167-179, 2014
652014
Energy vs. ventilation rate in buildings: A comprehensive scenario-based assessment in the European context
HRR Santos, VMS Leal
Energy and Buildings 54, 111-121, 2012
562012
A methodology for sustainable and inclusive local energy planning
AR Neves, V Leal, JC Lourenço
Sustainable cities and society 17, 110-121, 2015
542015
Impact of using cool paints on energy demand and thermal comfort of a residential building
D Dias, J Machado, V Leal, A Mendes
Applied Thermal Engineering 65 (1-2), 273-281, 2014
512014
Urban form and energy demand: A review of energy-relevant urban attributes
M Silva, V Oliveira, V Leal
Journal of Planning Literature 32 (4), 346-365, 2017
462017
Modelling the relationship between heating energy use and indoor temperatures in residential buildings through Artificial Neural Networks considering occupant behavior
SMC Magalhães, VMS Leal, IM Horta
Energy and Buildings 151, 332-343, 2017
452017
“SOLVENT”: development of a reversible solar-screen glazing system
E Erell, Y Etzion, N Carlstrom, M Sandberg, J Molina, I Maestre, ...
Energy and Buildings 36 (5), 467-480, 2004
372004
A sustainability assessment of advanced materials for novel housing solutions
P Samani, A Mendes, V Leal, JM Guedes, N Correia
Building and Environment 92, 182-191, 2015
342015
Setting targets for local energy planning: Critical assessment and a new approach
VMS Leal, I Azevedo
Sustainable Cities and Society 26, 421-428, 2016
312016
Occupants’ behaviour in energy simulation tools: lessons from a field monitoring campaign regarding lighting and shading control
P Correia da Silva, V Leal, M Andersen
Journal of Building Performance Simulation 8 (5), 338-358, 2015
312015
Strategies to control daylight in a responsive skylight system
GC Henriques, JP Duarte, V Leal
Automation in Construction 28, 91-105, 2012
302012
O sistema não pode efectuar a operação agora. Tente novamente mais tarde.
Artigos 1–20